Thermalstore
4
The instructions are an integral part of the appliance and must be given to the end
user on completion of the installation in order to comply with the current regulation.
It is important to carefully read the manual to understand all the information to ena-
ble safe installation, use and servicing. These instructions consist of details for instal-
lation, servicing, fault fi nding and replacement of parts for the cylinder purchased.
JOULE will not accept any liability in the event of damage for not complying with the
guidance in this instruction manual.
The instructions for this installation manual apply to the range of JOULE Cyclone
Indirect Unvented Cylinders.
Safety is paramount when installing unvented hot water systems and the following
instructions must be adhered to:
Only certifi ed competant installers can install, commission and service the equipment
supplied.
The cylinder must be used for potable hot water only. Any other applications will be
considered incorrect use and JOULE will not be held liable for any losses resulting
from such use.
All installation and maintenance instructions must be observed to ensure the correct
operation of the equipment.
The electric immersion must not be switched on unless the cylinder is completely full
of water.
Domestic hot water may be stored at temperatures exceeding 60°C. Preventative
measures should be put in place to negate the possibility of scalding.
A maintenance schedule should be put in place with a competent person to service
the equipment annually to comply with the warranty conditions.
When servicing the system the mains supply to the cylinder should be isolated.
Only genuine spare parts should be used. A full list of items with relevant codes can
be found on page 13 .
The installation must be carried out by a person competent to install unvented hot
water systems. The installation must be carried out in accordance with the following
recommendations:
Introduction
Summary of Contents for Thermalstore 1.0
Page 1: ...1 Thermalstore 1 0 2 0 Installation Manual...
Page 16: ...Thermalstore 16 Thermalstore 1 0 No Solar...
Page 18: ...Thermalstore 18 Thermalstore 1 0 Solar...
Page 20: ...Thermalstore 20 Thermalstore 2 0 No Solar...
Page 22: ...Thermalstore 22 Thermalstore 2 0 Solar...
Page 25: ...25 Electrical Diagram...
Page 27: ...27 Electrical Diagram...
Page 29: ...29 Electrical Diagram...
Page 30: ...Thermalstore 30 Thermalstore Sealed Boiler 2 Radiator Zones Solar Mechanical Diagram...
Page 31: ...31 Electrical Diagram...
Page 32: ...Thermalstore 32 Thermalstore Open Vent Boiler 1 Radiator Zones Mechanical Diagram...
Page 33: ...33 Electrical Diagram...
Page 34: ...Thermalstore 34 Thermalstore Open Vent Boiler 2 Radiator Zones Mechanical Diagram...
Page 35: ...35 Electrical Diagram...
Page 36: ...Thermalstore 36 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 37: ...37 Electrical Diagram...
Page 38: ...Thermalstore 38 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 39: ...39 Electrical Diagram...
Page 41: ...41 Electrical Diagram Electrical Diagram...
Page 43: ...43 Electrical Diagram...
Page 45: ...45 Electrical Diagram...
Page 47: ...47 Electrical Diagram...
Page 64: ...Thermalstore 64 Mains Pressure Hot...
Page 65: ...65 Water Storage System Commisioning Checklist...
Page 66: ...Thermalstore 66...
Page 67: ...67 Service Record...