4
139760_A GF 500 DV Oct. 2017
25”
535 mm
28 1/2”
724 mm
23”
584 mm
17 1/2”
445 mm
5 1/2”
140 mm
30 1/8”
785 mm
5 7/8”
11 7/8”
300 mm
27 3/4”
704 mm
30”
762 mm
25 7/8”
657 mm
16 3/4”
425 mm
22 1/2”
572 mm
21 1/4”
540 mm
Safety Screen Barrier
PN 157691
GF
500
DV
Specifications
Input Rates
Natural Gas
40,000 BTU/hr. maximum input
12,800 BTU/hr. minimum input
Propane
39,500 BTU/hr. maximum input
14,000 BTU/hr. minimum input
Inlet Pressure:
MIN MAX
Natural Gas:
5.0 WC (1.25 kPa) 7.0 WC (1.74 kPa)
Propane:
12.0 WC (3.0 kPa) 14.0 WC (3.48 kPa)
Manifold Pressure:
MIN
MAX
Natural Gas:
1.2 WC (.30 kPa) 3.80 WC (.95 kPa)
Propane:
2.9 WC (.72 kPa) 11.0 WC (2.74 kPa)
• SIT Nova 820 Millivolt System - Piezo Ignitor
• Steady State Efficiency: NG - 74.26% LP - 77.02%
• AFUE Efficiency: NG - 67.00% LP - 67.40%
• CSA P4.1-15 Fireplace Efficiency:
NG - 74.25% LP - 75.01 %
• Factory Air Shutter Settings: NG - 1/16” LP - 1/8”
• Ambient Temperature Range: 32 - 212°F (0 - 100°C)
Nova 820 High-Temp Valve
Height Dimensions with Optional Short Legs:
- subtract 2 1/4 in. (57 mm)
Figure 1. Dimensioned views, GF 500 DV
FAMILIARIZE YOURSELF WITH THE VENTING,
CLEARANCE AND OTHER INSTALLATION
REQUIREMENTS IN THIS MANUAL BEFORE BEGINNING
THE INSTALLATION.
THIS APPLIANCE IS SHIPPED FROM THE FACTORY FOR
USE WITH NATURAL GAS ONLY. FOR USE WITH PROPANE,
THE APPLIANCE MUST FIRST BE CONVERTED USING THE
FUEL CONVERSION KIT PROVIDED, #157865. CONVERSION
SHOULD BE MADE BEFORE THE APPLIANCE IS INSTALLED.
SEE PG. 17.