background image

2

139760_A   GF 500 DV  Oct. 2017

 �

We recommend that 

our gas products be 

installed and serviced by 

professionals who are 

certified in the U.S. by 

the National Fireplace 

Institute® (NFI) as NFI Gas 

Specialists.

THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE 

SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION 

OF THIS APPLIANCE. PLEASE READ THESE INSTRUCTIONS IN 

THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE 

USING OR SERVICING THIS GAS STOVE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION 

OF THIS APPLIANCE OR ITS COMPONENTS.  ANY 

MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, 

CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS APPLIANCE MUST BE INSTALLED AND MAINTAINED BY A 

QUALIFIED SERVICE TECHNICIAN OR AGENCY.  

 

Suggested Tools for  

Installation and Service

•  External regulator (for Propane only)

•  Piping which complies with local code

•  Manual shut-off valve -  

  T-Handle required in Massachusetts

•  Sediment trap - if required by code

•  Tee joint

•  Pipe wrench

•  Pipe sealant

•  10 mm open end wrench

•  1/2”, 7/16” open end wrench

•  Phillips head screwdriver

•  Flat head screwdriver

•  1/4” nut driver

• Gloves

•  Safety glasses

•  Torx T-20 screwdriver 

•   Tin snips

Installation Requirements for the 

Commonwealth of Massachusetts

THIS PRODUCT MUST BE INSTALLED BY 

A LICENSED MASTER OR JOURNEYMAN 

PLUMBER OR GAS-FITTER WHEN 

INSTALLED IN THE COMMONWEALTH OF 

MASSACHUSETTS.

1.   If there is not one already present, 

on each floor level where there are 

bedroom(s), a carbon monoxide detector 

and alarm shall be placed in the living 

area outside the bedroom(s). The carbon 

monoxide detector shall comply with 

NFPA 720 (2005 Edition).

2.   A carbon monoxide detector shall:  

a)  Be located in the room that houses the 

appliance or equipment;

  b) Be either hard-wired or battery 

powered or both; and

  c)  Shall comply with NFPA 720 (2005 

Edition).

3.   A Product-approved vent terminal must 

be used, and if applicable, a Product-

approved air intake must be used. 

Installation shall be in strict compliance 

with the manufacturer’s instructions.  A 

copy of the installation instructions must 

remain with the appliance or equipment 

at the completion of the installation.

PLEASE NOTE:

It is normal for smoke and odor to occur during 

the initial stages of operation, depending upon 

temperatures generated over time. This “curing” 

condition can be alleviated by promoting fresh 

air circulation within the immediate vicinity of 

the appliance.

Natural Gas  /  74.25% 

Propane        /  75.01%

Jøtul GF 500 DV

Based on CSA P.4.1-15

Summary of Contents for GF 500 DV IPI

Page 1: ...service must be performed by a qualified installer service agency or the gas supplier In the Commonwealth of Massachusetts a carbon monoxide CO detector shall be installed in the same room as the appl...

Page 2: ...wdriver Tin snips Installation Requirements for the Commonwealth of Massachusetts THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS FITTER WHEN INSTALLED IN THE COMMONWE...

Page 3: ...ltitude Adjustment 21 Optional Wall Thermostat 22 Optional Brick Panel Installation 22 Optional Blower Installation 23 Log Set Installation 25 System Check 26 Flame Picture Adjustment 27 Operation Gui...

Page 4: ...2 9 WC 72 kPa 11 0 WC 2 74 kPa SIT Nova 820 Millivolt System Piezo Ignitor Steady State Efficiency NG 74 26 LP 77 02 AFUE Efficiency NG 67 00 LP 67 40 CSA P4 1 15 Fireplace Efficiency NG 74 25 LP 75 0...

Page 5: ...ay be installed with the stove doors either open or closed 2 Remove the Top Plate of the stove by simply lifting it straight off of the stove body 3 To open the firebox a Remove four hex head screws u...

Page 6: ...ssembly 2 Remove four screws on the rear exhaust cover plate and re install the cover plate over the top outlet Figs 4 and 5 3 Orient the vent adaptor outlet to the rear and secure the assembly using...

Page 7: ...qualified service technician to inspect the heater and to replace any part of the con trol system and any gas control which may have been under water Safety Information Due to the high operating temp...

Page 8: ...e Floor Protection This appliance CANNOT be installed directly on carpeting vinyl linoleum or wood laminate flooring such as Pergo If this appliance will be installed on any combustible material OTHER...

Page 9: ...in 958 mm D 36 1 4 in 921 mm A 54 1 2 in 1384 mm B 53 in 1346 mm C 51 1 2 in 1308 mm D 50 in 1270 mm Figure 10 Minimum Alcove Clearances Figure 8 Parallel Installation Clearances E 48 1 2 in 1232 mm F...

Page 10: ...OM DIFFERENT MANUFACTURERS IN THE SAME SYSTEM Installation of any components not manufactured or approved by J tul or failure to meet all clearance requirements will void all warranties and could resu...

Page 11: ...Figure 14 Use 1 4 socket driver to loosen the Exhaust Restrictor dial and adjust to the appropriate notch for your termination zone Figure 15 Vent Termination Zone Matrix NG LP APPLICABLE TO BOTH CO A...

Page 12: ...rby trees and predominantly windy conditions can contribute to poor draft and or promote draft reversal Increasing the height of the vent may alleviate these conditions Use Wall Straps to support an o...

Page 13: ...ND 6 FEET BEYOND THE DAMPER AREA OF THE FIREPLACE If the intake flex duct does not extend the full length of the chimney and connect to both the unit and the termination cap A METAL BLOCK OFF PLATE MU...

Page 14: ...Series pipe from stove to thimble 4 Flex Pipe not included in kit Support Wall Thimble Cover Horizontal Termination Any horizontal termination must fall within the shaded portion of the vent window ma...

Page 15: ...be no more than 24 in 610 mm One 45 Elbow may be used for a corner installation as shown in fig 23 Exhaust Restriction Under normal circumstances no exhaust restriction is recommended Keep the factor...

Page 16: ...within a height 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 3 ft 91 cm J Clearance to nonmechanical air supply inlet to building or the combustion air inlet...

Page 17: ...INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION IN CANADA THE CONVERSION SHALL BE CARRIED OUT IN ACC...

Page 18: ...all the identification labels to the stove so that they can be seen by any person who may be servicing the stove Label A apply to back of stove Label B apply to the rating plate attached to the back o...

Page 19: ...to remove it from the firebox Figure 34 Re secure the modified Secondary Baffle REMOVE BAFFLE W PERFORA BAFFLE T REMOVE TWO 8 SCREWS TO LOOSEN THE BAFFLE WING USING PLIERS BEND THE PERFORATED PORTION...

Page 20: ...a gas shut off valve gas cock and union to be installed in the supply line and in the same room as the appliance This allows for the disconnection of the stove for servicing and maintenance See fig 36...

Page 21: ...ustment to the burner If the gas supplier does not derate fuels install High Altitude Adjustment Kit 157695 for Propane and Kit 157696 for Natural gas U S Canada per ANSI Z21 88 2014 CSA 2 33 2014 CAN...

Page 22: ...ostat should be connected to the terminal block using a minimum of 16 gauge wire with a maximum length of 25 feet of wire Connect either of the two thermostat wire leads to either of two terminals on...

Page 23: ...ch See fig 42 3 Attach the Blower Bracket to the stove using the two M6 flange head hex bolts as shown in fig 42 4 Remove the Air Deflectors 7 from the blower duct openings 5 Install the Blower with t...

Page 24: ...be manually adjusted using the control knob If the burner turns off the blower will be shut off automatically when the stove cools down If automatic blower circulation is not desired place the blower...

Page 25: ...that the pilot carry over ports are not obstructed Figure 47 Set the Rear Lower Left and Lower Right logs onto the burner base as shown 1 2 3 4 5 6 A quantity of ember stones is included with the log...

Page 26: ...ilot flame should engulf the thermocouple and thermopile and project from the pilot hood forward to the burner carry over ports Adjust pilot flame intensity using the adjustment screw located to the r...

Page 27: ...combustion in the flames and lack of combustion air entering the air shutter opening To adjust the air shutters 1 Reach under the stove and loosen the Air Shutter wing nuts The RIGHT shutter controls...

Page 28: ...l and manufacturing materials cure under heat This condition is temporary and can be alleviated by allowing plenty of fresh air to circulate through the area 3 Condensation may develop on the glass up...

Page 29: ...are fragile Vacuum more frequently if there are pets in the home The pilot assembly should be inspected and cleaned annually by a qualified technician Any component showing corrosion should be replac...

Page 30: ...ALLATION IN A MANUFACTURED MOBILE HOME AND MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AND THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD TITLE 24 CFR PART 3280 THIS A...

Page 31: ...Magnet 5 224909 Magnet Cap Hi temp Vinyl 9 225453 Base Plate 10 225601 Bracket Side to Base 11 22557092 Top Convection Shroud 12 22584192 Rear Shroud 13 157712 Vent Adaptor Assembly 14 225459 Exhaust...

Page 32: ...ipple 3 8 NPT x 2 5 8 222407 Shut off Valve 3 3 FIP x 3 8 FIP 9 222292 Elbow 3 8 NPT x 3 8 Flare 10 22583992 Control Bracket MB 11 117588 Washer Hinge 12mm OD x 6mm ID 12 9962 Bolt Hex M6 x 10 DIN 933...

Page 33: ...op in Assembly 11 222280 Gasket Drop in Orifice Holder 12 225536 Orifice 2 25 mm Left Rear Flames NG 129804 Orifice 1 40 mm Left Rear Flames LP 13 220976 Orifice 47 Right Front Flames NG 221185 Orific...

Page 34: ...451 Ember Stones 8 157259 Rock Wool 1 oz 9 157706 Complete Log Set No Part No Description 1 22545492 Glass Frame 2 225476 Glass Panel Ceramic 3 129124 Gasket Tadpole 25 dia x 1 25 6 ft 4 220042 Replac...

Page 35: ...n conformance with the installation instructions contained in this owner s manual or local and or national fire and building regulations 3 Damage due to service performed by an installer service agenc...

Page 36: ...36 139760_A GF 500 DV Oct 2017 This page is intentionally blank...

Page 37: ...37 139760_A GF 500 DV Oct 2017 This page is intentionally blank...

Page 38: ...38 139760_A GF 500 DV Oct 2017 This page is intentionally blank...

Page 39: ...rol knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this...

Page 40: ...ations October 2017 139760_A Your stove has a unique serial number stamped on the rating plate which is hung on the back Please record the serial number in the space below You may also wish to attach...