22
139760_A GF 500 DV Oct. 2017
Optional Double-sided
Brick Panel Kit 157697
1. Locate the retainer tabs in the upper corner of each
side of the firebox. Bend each retainer tab out enough
to engage the side brick panels. See fig. 40.
2. Install the Lower Panel, (the smaller of the two
rectangular panels.)
Position it up against the back wall, resting on the rear
shelf.
3. Set the Upper Panel on the Lower Panel. Hold those
panels in place while setting one Side Panel on the
shelf beside the burner and under its retainer tab. Bend
the retainer down to fully engage the side panel.
4. Engage the opposite matching Side Panel under its
retainer tab and seat it against the wall. Bend that
retainer tab down to secure the panel in place.
Optional Wall Thermostat 750003
Use only a 750 millivolt DC two-wire circuit wall
thermostat with this appliance. The thermostat should
be placed in the same room as the heater, typically 5
feet off the floor. Avoid drafty areas or any area that may
affect the accuracy of the thermostat.
The thermostat should be connected to the
terminal block using a minimum of 16 gauge wire with a
maximum length of 25 feet of wire.
Connect either of the two thermostat wire leads to
either of two terminals on the terminal block located to
the right of the main gas valve. Do not overtighten the
connections.
IT IS NOT NECESSARY TO DISCONNECT ANY
OTHER WIRES.
See Fig. 39.
For thermostatic operation, the On/Off/T-Stat switch
on the back of the stove must be in the T-stat position,
and the pilot light must be running, as it is the power
source for the thermostat.
At the thermostat, the two wires should be connect-
ed to the two connection screws on the thermostat base
plate per the manufacturer’s instructions.
Optional Remote Control 224910
When using a remote, the remote receiver should be
wired to the terminal block in the same way the as the
thermostat. See the instructions above.
Follow the operating instructions included with the
Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING
THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER OR
DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION
AFTER SERVICING THE APPLIANCE.
Accessories
Figure 39. Accessory wiring diagram.
Figure 40. Install the Brick Panels.