24
139760_A GF 500 DV Oct. 2017
Blower Operation
The optional variable-speed blower will enhance heat
circulation around the firebox and out into the room. The
blower is controlled by a heat activated switch (snap-
stat) that will ONLY function when the control switch
is in AUTO setting. After the fire has been burning for a
time, the snapstat will react to the heat and activate the
blower. Fan speed may be manually adjusted using the
control knob. If the burner turns off, the blower will be
shut off automatically when the stove cools down.
If automatic blower circulation is not desired, place
the blower control switch in the MANUAL position.
Wing screw
Male Quick-connector to
Female Quick-connector
Snapstat
Figure 45. Blower Wiring Diagram
Figure 43. Attach Blower to the Mounting
Bracket with the wing screw and connect
wire harnesses to the Snapstat and
controls quickconnection.
Figure 44. Blower Controls
BR
BK
W
G
GY
BK
BK
BK
BK
BL
AUTO OFF MANUAL
GY
BR
BK
W
G
BL
BK
= QuickConnector Pin
Speed Control