3
Intended use
Complying with the instructions provided in this document will
make it possible to avoid dangers and prevent damage to the land-
ing gear.
3.3
Application limits
The application limits for the landing gear are as follows:
Operating temperature range -20 °C to +85 °C. When in its
rest position, the system can be exposed to a temperature of
95 °C for maximum 2 hours (e.g. during repainting).
Max. static test load depending on the winch type is up to 25
t per support, the information on the type plates of the par-
ticular landing gears applies.
Lifting load max. 12 t per support (lifting a load is only permit-
ted in low gear)
Horizontal set-up location on consolidated ground (place suit-
able underlay boards underneath if necessary), in compliance
with any relevant national regulations concerning maximum
floor loading.
3.4
Principle
The landing gear is a state-of-the-art product in accordance with
the applicable safety and occupational health regulations. Never-
theless, the following dangers can arise if it is used incorrectly or
misused:
Danger of serious or fatal injury to the user of third parties.
Danger of damage to the landing gear and other property of
the owner.
Danger to efficient use of the landing gear.
8
MUB 006 001 M01
(REV-D)
07-2020
Modul E-Drive