Installation
ADVICE!
Follow the specifications (e.g. installation directive)
of the vehicle manufacturer when connecting the
supply line to terminal 15 or 30 and terminal 31. A
corresponding connection must be provided on the
tractor vehicle and must be fused with at least 15 A
(preferably with a circuit breaker). This can take the
form of a separate socket or a suitably fused stan-
dard socket. Follow the specifications (e.g. installa-
tion directive) of the semi-trailer tractor and vehi-
cle manufacturer when doing this.
Vehicles that are used in ADR conditions must com-
ply with the relevant statutory regulations.
If it is installed on a semi-trailer for hazardous sub-
stances in classes FL, AT and OX pursuant to ADR,
the technical features required for ADR vehicles of
the named classes must be retained.
The Modul E-Drive must be supplied in full through
the battery isolation switch and thus does not
meet the "permanently supplied circuits" technical
features under ADR regulations.
Make sure that a minimum cross section of 2.5
mm² is provided if using an adapter in the general
electrical power supply.