8
Maintenance work
Various maintenance activities are essential for ensuring that the
landing gear will operate correctly over a long period.
The maintenance work comprises the following:
Cleaning
Maintenance
ATTENTION!
Only use genuine parts in consultation with JOST. Other-
wise, liability and warranty claims could be invalidated.
WARNING!
Neglecting maintenance work has a significant effect on
the correct function and safety. It is possible that liability
and warrant claims might be invalidated.
The maintenance work is described in the following chapters.
8.1
Checking and renewing fuses
ADVICE!
This work is exclusively allowed to be carried out by
trained specialist personnel, otherwise it is possible for
damage to be caused to the electronic circuit board, e.g.
by electrostatic discharge.
Remove the housing cover as described in chapter "7.4
Optional changeover to 20 A".
Check the fuse (no. 1) and renew it if necessary.
When doing this, note that it is exclusively permitted for
blade fuses according to ISO 8820-3 to be used.
Assembly is carried out as described in chapter "7.4 Optional
changeover to 20 A".
32
MUB 006 001 M01
(REV-D)
07-2020