18
08
09
MIn
3 mm
10
Fig. 08: Wash the mesh under running hot
water and dry it thoroughly with a cloth.
attention: ensure that the mesh is
perfectly dry before putting it back!
Fig. 09: Put the outer metal mesh back on
the glass tube so that it fully overlaps the
internal plate.
In any case ensure a minimum
distance of at least 3 mm from
the base of the generator.
Fig. 10: Screw the ionizing generators
back into place by acting again on the
glass surface that can be reached by hand
through the special slots.
aTTenTIon: do not overtighten the screw
after reaching its end stop.
check that the earthing spring
is in contact with the outer
mesh once the ionising tubes
have been screwed back into
place. otherwise contact the
manufacturer.
The manufacturer is not liable
for any damage to the device
caused by the presence of hu-
midity or water on the outer
mesh.