17
05
04
06
07
Fig. 05: Remove the lid by pulling it
upwards.
Fig. 04: Put the device on a flat surface.
Remove the plug connected to the mains.
Fig.
06: Gently unscrew the ionising
generators by acting on the glass surface
that can be reached by hand through
the special slots. Remove the mesh
surrounding the tube.
If this is too difficult, turn the
mesh slightly around the glass.
Fig. 07: Clean the glass using a damp
cloth.
Do not use liquid cleaners or
sprays, soap or the like.
Check that the ionizing generator is in good conditions: there must not be any cracks
or other damage; otherwise it must be replaced.
As soon as you notice a whitish layer on the perforated metal plate inside the glass it
means that the ionising generator needs replacing.
The ionizing generators must usually be replaced within 18 months of use.