6 D-304956 BW-DTM Istruzioni di installazione / Installation Instructions / Instrukcja instalacji
The following table indicates the received signal strength indication.
LED response
Reception
Green LED blinks
Strong
Orange LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the detector, re-locate it and re-test until a "good" or "strong"
signal strength is received.
For detailed Diagnostics Test instructions refer to the control panel Installer Guide.
3.
EVENT INDICATIONS
LED Indications
Event
Red LED blinks
Stabilization (warm-up 120 sec)
Red LED ON 0.2 sec.
Tamper open / close
Red on 2 sec.
Intruder alarm
Yellow LED on
AM detection
– diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF)
AM detection
– Normal mode
Yellow and red LED blink simultaneously (0.2 sec. ON [both], 0.2 sec. OFF)
Self -test failure
– Diagnostic mode
Yellow and red LED blink simultaneously slowly (0.2 sec. ON [both], 30 sec. OFF)
Self -test failure
– Normal mode
Green LED blinks
PIR detection
– Microwave adjustment mode
Green LED on
Microwave detection
– Microwave adjustment mode
4.
MICROWAVE ADJUSTMENT / TESTING
The aim of the adjustment/testing is to enable adjustment and testing of the MW sensitivity. In this mode the MW operates continuously and independently of early activation of the PIR. For
adjustment/testing procedure instructions, refer to the BW Installation Guide, Periodic Test.
5.
SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection, malicious masking of the lens, tampering with the optical
system, decreased sensitivity in ambient temperatures close to that of the human body and unexpected failure of a component part.
The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore recommended that the detector and the entire alarm system be
checked weekly, to ensure proper performance
.
6.
COMPLIANCE WITH STANDARDS
Europe: EN 301 489, EN 50130-4, EN 300 220, EN 62368-1, EN 50131-5-3, EN 50130-5, EN 50131-1, EN 50131-6 Type C, EN 50131-2-4, Grade 2, Class II.
Hereby, Bentel Security S.r.l. declares that the radio equipment type BW-DTM is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available
at the following internet address:
http://www.bentelsecurity.com/dc
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for
.
This product is not to be thrown away with everyday waste
upplier.
repair then you must ensure that it is returned as identified by your s
Directive 2012/19/EC Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
GENERAL
Detector Type
Dual element low-noise pyroelectric sensor
Lens Data
No. of Beam Elements:
18x3=54 far parabolic mirror segments
No. of Curtain Elements:
18
MW Coverage
(see figure 5)
Maximum:
15 m (49 f t) / 90°
Medium:
10 m (33 f t) / 90°
Minimum:
5 m (16 f t) / 90°
Pet Immunity
Up to 40 kg (90 lb)
ELECTRICAL
Sensor Type
K-Band Doppler module: 24 GHz
Power Supply
Type C
Internal Battery
3V Lithium battery, type CR-123A or equivalent
Nominal Battery Capacity
1450 mAh
Battery Life (for typical use)
5 years
FUNCTIONAL
True Motion Event Verification
2 remote selections - high sensitivity or low sensitivity
Alarm Period
2 seconds
WIRELESS
Frequency Band (MHz)
868-869
Maximum Tx Power
14dBm @ 868MHz
Communication Protocol
PowerG
Supervision
Signaling at 4-min. intervals
Tamper Alert
Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored
MOUNTING
Height
1.8
– 3.0 m (6 - 10 ft).
Installation Options
Surface or corner
ENVIRONMENTAL
RFI Protection
>20 V/m up to 2000 MHz, excluding in band frequencies
Operating Temperatures
-10°C to 55°C (14°F to 131°F) indoor
Storage Temperatures
-20°C to 60°C (-4°F to 140°F)
WARNING! Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.