D-304956 BW-DTM Istruzioni di installazione / Installation Instructions / Instrukcja instalacji 5
2.3. Enrollment
Refer to the BW control panel's Installer Guide and follow the procedure under the
"02: ZONES / DEVICES"
option of the Installer Menu. A general description of the procedure is provided in the
following flow chart.
Step 1
Step 2
Step 3
Step 4
Step 5
Enter the Installer menu and select
“
02: ZONES / DEVICES
”
Select "
ADD NEW DEVICE
"
See Note 1
Enroll the device or enter the
device ID
Select the desired detector
number for the new detector
Configure Location, Zone
Type & Chime
Parameters
02:ZONES/DEVICES
ADD NEW DEVICES
ENROLL NOW or
ENTR ID:XXX-XXX X
Z14: Motion Sens
ID No. 123-XXXX
Z14.LOCATION
Z14.ZONE TY PE
Z14.
SET CHIME
Step 6
Step 7
Step 8
Enter PARTITIONS.
See Note 2
Assign partitions to the detector by
pressing the
,
and buttons on the panel
Select the "DEV SETTINGS" option
and refer to the section below to
configure the detector parameters.
F02:P1
◼
P2 P3
◼
F02: DEV SETTINGS
means scroll
and select
Notes:
1.
If the detector is already enrolled, you can configure the detector parameters and assign partitions via the “Modify Devices” option – see Step 2.
2.
PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details, see "Partitioning" in the BW Installation Guide).
2.4 Configuring the Detector Parameters
Enter the
DEVICE
menu and follow the configuration instructions for the BW-DTM detector as described in the following table
Option
Configuration Instructions
Define whether the alarm LED indication will be activated.
Optional settings:
ON
(default) and
OFF
.
Define the detection range of the microwave channel.
Optional settings:
Maximum
(default);
Medium
and
Minimum
.
Define whether an alarm will be activated upon continued motion (low sensitivity) or upon a single alarm event (high sensitivity).
Optional settings:
LOW sensitive
(default) and
HIGH sensitive
.
Define whether or not to set the activity time during disarm.
Optional settings:
NOT Active
(default),
YES
– no delay
,
YES + 5s delay
,
YES + 15s delay
,
YES + 30s delay
,
YES + 1m delay
,
YES
+ 2m delay
,
YES + 5m delay
,
YES + 10m delay
,
YES + 20m delay
and
YES + 60m delay
.
Define the activity and the sensitivity level of the PIR anti-masking.
Optional settings:
LOW sensitive
(default),
HIGH sensitive
and
disabled
.
Define whether to enable or disable the anti-masking of the microwave sensor.
Optional settings:
disabled
(default) and
enabled
.
Disguise mode is used to detect movement of an intruder who cloaks his IR radiation to avoid detection. Define whether to enable or
disable this mode.
Optional settings:
disabled
(default) and
enabled
.
3
LOCAL DIAGNOSTICS TEST
A.
Separate the base from the cover (see Fig. 3).
B.
Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case closure screw.
C.
The BW-DTM will enter a 2 min. stability period. During this time the red LED blinks.
D.
Walk-test the coverage area - see Figure 5. Walk across the far end of coverage pattern in both directions; the red LED lights each time your motion is detected followed by 3 LED blinks
Alarm LED
MW RANGE
EVENT COUNTER
DISARM Activity
ANTI MASKING
MW ANTI
MASKING
DISGUISE MODE
Z14.LOCATION TYPE
ADD NEW DEVICES
ENROLL NOW or
Z14:MOTION SENS
ID NO. 123-XXXX
MODIFY DEVICES
Z14:PARTITIONS
F02:P1
✓
P2 P3
✓
F02:DEVICESETTINGS
ENTR ID:XXX-XXXX
Z14. LOCATION
Z14.SET CHIME
02:ZONE / DEVICES