PMGB0406B rev.1
7
DO NOT lift air handler by the cabinet braces. The cabinet braces are held in place by the coil channels. The
cabinet braces could become disengaged from the cabinet causing the air handler to fall, potentially causing
injury or damaging property. See Figure 1 for location of cabinet braces. Lift the air handler by tightly gripping
the casing.
8. It is necessary to maintain clearances for servicing. Allow access to electric heaters and blower.
9. Verify the unit rating plate and power supply to ensure that the electrical characteristics match.
10. You must install air handler so the electrical components are protected from water.
11. Installing and servicing heating/cooling equipment can be hazardous due to the electrical components.
Only trained and licensed personnel should install, repair, or service heating/cooling equipment. Unlicensed
service personnel can perform basic maintenance functions such as cleaning and replacing the air
¿
lters.
When working on heating/cooling equipment, the precautions in the manuals and on the labels attached
to the unit and other safety precautions must be observed as applicable.
These air handlers should be transported and handled in an upright, up
À
ow position. Failure to do so may result
in unit damage and personal injury. Con
¿
guration conversions should be done at site of installation.
12. These instructions cover minimum requirements and conform to existing national standards and safety
codes. In some instances these instructions exceed certain local codes and ordinances, especially those
that have not kept up with changing residential and non-HUD modular home construction practices. These
instructions are required as a minimum for a safe installation.
Figure 1. Return Air Duct Attachment and Component Location
SIDE VIEW
RETURN AIR
DUCT
FRONT VIEW
SECONDARY DRAIN
UPFLOW 3/4” NPT
FILTER DOOR
WHEN ATTACHING DUCT WORK WITH
SCREWS - KEEP SCREWS WITHIN 5/8”
OF SIDES AND BACK OF AIR HANDLER
DUCT WORK MAY
BE FASTENED
CAUTIOUSLY WITH
SCREWS TO THE
SIDES AND REAR OF UNIT
PRIMARY DRAIN
3/4” NPT
VAPOR
REFRIGERANT
LINE CONNECTION
LIQUID
REFRIGERANT
LINE CONNECTION
HORIZONTAL
DRAIN PAN
VERTICAL
DRAIN PAN
COIL COMPARTMENT
(Access panel removed)
BLOWER
COMPARTMENT
SECONDARY DRAIN
HORIZONTAL FLOW
3/4” NATIONAL PIPE
THREAD (NPT)
A0328-001
CABINET BRACE
CABINET BRACE