SECTION 2 - PROCEDURES
2-20
– JLG Lift –
3121804
Changing the Access Level of the Hand Held
Analyzer:
When the analyzer is first connected, you will be in access
level 2 which enables you to only view most configuration
settings which cannot be changed until you enter a pass-
word to advance to a lower level. This ensures that a set-
ting cannot be accidentally altered. To change the access
level, the correct password must be entered. To enter the
password, scroll to the
ACCESS LEVEL
menu. For exam-
ple:
MENU:
ACCESS LEVEL 2
Press
ENTER
to select the
ACCESS LEVEL
menu.
Using the
UP
or
DOWN
arrow keys, enter the first digit of
the password, 3.
Then using the
RIGHT
arrow key, position the cursor to
the right one space to enter the second digit of the pass-
word.
Use the
UP
or
DOWN
arrow key to enter the second digit
of the password which is 3.
Repeat this process until you have entered all five digits of
the password which is
33271
.
Once the correct password is displayed, press
ENTER
.
The access level should display the following, if the pass-
word was entered correctly:
MENU:
ACCESS LEVEL 1
Repeat the above steps if the correct access level is not
displayed or you can not adjust the personality settings.
When a machine digit item is selected, press the
UP
or
DOWN
arrow keys to adjust its value, for example:
GROUND ALARM:
2=DRIVE
The effect of the machine digit value is displayed along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you
wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.
When selecting the machine model to match the size of
the machine, the personality settings will all default to the
factory recommended settings.
NOTE: Refer to the appropriate Machine Personality Set-
tings Table, and the Machine Setup Table in the JLG
Service Manual for the recommended factory set-
tings.
Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality settings.
CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE
PERFORMANCE OF YOUR MACHINE.
IMPORTANT
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.
Summary of Contents for 330CRT
Page 1: ...Service Maintenance Manual Model 330CRT 400CRT 3121804 April 7 2004 ...
Page 2: ......
Page 8: ...TABLE OF CONTENTS iv JLG Lift 3121804 This page left blank intentionally ...
Page 12: ...SECTION 1 SPECIFICATIONS 1 4 JLG Lift 3121804 Figure 1 1 Torque Chart ...
Page 22: ...SECTION 2 PROCEDURES 2 8 JLG Lift 3121804 Figure 2 3 400CRT LIft Cylinder ...
Page 54: ...SECTION 3 TROUBLESHOOTING 3 12 JLG Lift 3121804 Figure 3 3 Hydraulic Schematic Sheet 1 of 2 ...
Page 56: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Lift 3121804 This page intentionally left blank ...
Page 57: ......