113161-14
01422 822282
41
SECTION VIII
REVERSING TIMER SPIN / DWELL ADJUSTMENTS
(FOR NON-COIN MECHANICAL TIMER MODELS ONLY)
Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is
located in the upper rear area of the dryer.
Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the
electronic timer (as noted in the
illustration below
).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
30
60
90
120
150
DWELL (STOP) TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
5
6.3
7.6
8.9
10.2
* Values shown are +/- 1-second.