Clean the steam coil fins. It is suggested that compressed air and a vacuum cleaner with brush attachment be used.
WARNING:
When cleaning steam coil fins, be careful not to bend the fins. If fins are bent,
straighten by using a fin comb, which is available from local air-conditioning supply
houses.
90 DAYS
Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal
exhaust ducting.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD
.
WARNING:
DO NOT
OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
WARNING:
INSPECT AND REMOVE ANY LINT ACCUMULATION, WHICH CAN CAUSE
THE BACK DRAFT DAMPER TO BIND OR STICK.
NOTE:
A back draft damper that is sticking partially closed can result in slow drying and shutdown
of heat circuit safety switches or thermostats.
NOTE:
If the hi-limit trips due to a high temperature occurrence, you must disconnect power before
resetting. To reset, press and release the reset button, which is located in the burner area of
the dryer.
NOTE:
When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, setscrews, grounding connections, and nonpermanent gas connections (unions, shutoff
valves, and orifices). Motor and drive belts
should be
examined. Cracked or seriously frayed belts
should be
replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete
operational check of
ALL
safety devices (door switches, sail switch, burner, and hi-limit thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and under normal/most conditions the basket (tumbler) bearings are permanently
lubricated. It is physically possible to relubricate the basket (tumbler) bearings if you choose to do so even though
this practice is not necessary. Use Shell Alvania #2 or its equivalent. The basket (tumbler) bearings used in the
dryer
DO NOT
have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting,
which can be obtained elsewhere, or from
JLA