113161-14
01422 822282
13
VERTICAL VENTING
When vertical single venting is used, the minimum duct size is 10-inches (25.4 cm) refer to
Illus. B below
, the
ductwork from the dryer to the outside outlet
cannot
exceed 60 feet (18.29 meters), refer to
Illus. B
below
. This
calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the
180° (turned downward) outside outlet.
Illus. B
If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross section area
of the ductwork
must be
increased in proportion to the number of elbows or duct run added.
IMPORTAN
T
:
For extended ductwork runs, the cross section area of the duct can only be increased
to an extent. For extended ductwork runs, a professional heating, ventilating, and
air-conditioning (HVAC) firm
should be
consulted for proper venting information.