ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.
When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For
others, calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
NON-REVERSING
120
1ø
2
8.7
—
15
208
1ø
2
5.5
—
15
220
1ø
2
4.5
3.9
15
230
1ø
2
3.2
3.5
15
240
1ø
2
4.8
4.6
15
208
3ø
3
3.1
—
15
220
3ø
3
3.1
3.9
15
240
3ø
3
3.3
4.2
15
460 / 480
3ø
3
2.1
—
15
230
3ø
3
—
3.5
15
380-400
3ø
4 or 3
—
2.2
15
416
3ø
4 or 3
—
2.3
15
REVERSING
208
3ø
3
5
—
15
220
3ø
3
5.2
6.8
15
240
3ø
3
5.6
7.4
15
380
3ø
3
5.4
—
15
460 / 480
3ø
3
3.2
—
15
230
3ø
3
—
6.2
15
380-400
3ø
4 or 3
—
3.4
15
416
3ø
4 or 3
—
3.5
15
2. Electrical Service Specifications
a. Gas and Steam Models Only
Check your national and local code for breaker and wire size