Jetter AG
Programming | 8
jxm-io-ew30_ba_2151_manual
40 / 56
8.4 Saving settings permanently and resetting to default values
The following parameters are permanently stored in the EEPROM:
■
PDO Mapping
■
All IO interface assignments and parameters
■
Producer heartbeat time
Save settings
Index
Subindex
Description
Type
Type of
access
Default
value
0x1010
0
Number of supported entries
U8
R
1
1
Saving all parameters
U32
R/W
When the specific signature 0x65766173 ("save") is written, the pa-
rameters are saved.
Tab. 34:
Save settings in EEPROM
Resetting the settings to their default values
Index
Subindex
Description
Type
Type of
access
Default
value
0x1011
0
Number of supported entries
U8
R
1
1
Command register
U32
R/W
1
When the specific signature 0x64616F6C ("load") is written, all set-
tings are reset to the default values.
Tab. 35:
Resetting the settings to their default values
INFO
Loading the settings from the EEPROM
During bootup, the last saved settings are automatically loaded.
During a firmware update, the settings may be reset to the default values.
Setting parameters
The parameters are set as follows:
1. The vehicle controller configures the parameters of the JXM-IO-EW30-G27.
2. The vehicle controller stores the settings via index 0x1010 in the EEPROM.
3. The vehicle controller reads the CRC via index 0x4556, subindex 1 and saves this value
locally in a remanent memory.
4. After a restart of the JXM-IO-EW30-G27 the vehicle controller compares the locally
stored CRC value with the value in index 0x4556, subindex 1. If the values do not
match, parameterization must be restarted.
INFO
Activating the Changes
The changes to the indices 0x1010 and 0x1011 only become active after a
restart.