Jetter AG
Programming | 8
jxm-io-ew30_ba_2151_manual
33 / 56
ID
Dez/Hex
Interface
Parameter
Values
Status
6
PWMO_HS3
High-side PWM
output (up to 3 A;
with precise cur-
rent measure-
ment)
PWM_FRQ
DITHER_FRQ
DITHER_AMP
MAX_CURRENT
OVERCURRENT_TIME
FILTER_DEEP
MIN_DEVIATION
MIN_CURRENT
OPENCIRCUIT_DETEC-
TION
SENSOR_SUPPLY
O_DUTY_CYCLE
I_HCURRENT
OVERCURRENT
SUPPLY_FAULT
ERROR
INACTIVE
OPEN_CIRCUIT
7
DO_HS3
High-side
digital output
(up to 3 A)
MAX_CURRENT
FILTER_DEEP
OVERCURRENT_TIME
MIN_DEVIATION
MIN_CURRENT
OPENCIRCUIT_DETEC-
TION
SENSOR_SUPPLY
O_DIGITAL
I_HCURRENT
OVERCURRENT
SUPPLY_FAULT
ERROR
INACTIVE
OPEN_CIRCUIT
8
Reserved
9
Reserved
10/a
CPWMO_HS3
High-side
output
(up to 3 A, with
current control)
PWM_FRQ
DITHER_FRQ
DITHER_AMP
CURRENT_CONTROL_P
CURRENT_CONTROL_I
CURRENT_CONTROL_D
CURRENT_CON-
TROL_TIME
MAX_CURRENT
OVERCURRENT_TIME
FILTER_DEEP
MIN_DEVIATION
MIN_CURRENT
OPENCIRCUIT_DETEC-
TION
SENSOR_SUPPLY
I_HCURRENT
O_HCURRENT
OVERCURRENT
SUPPLY_FAULT
ERROR
INACTIVE
CC_UNLOCK
OPEN_CIRCUIT