7 Description of Connections
74
Jetter AG
7.8
Connection Details for Digital
Outputs
*)
is connected to the GND of the control system
Fig.: 19: Connection details for digital outputs
Digital Outputs
Terminals X31
Signal
Specifications
DC 24 V
Power supply for the
outputs
DC 20 ... 30 V at I = max.
2 A (max. 0.5 A per output)
1
2
3
4
Digital output signals
(PNP outputs)
See
“Digital Outputs", page 40.
0 V
Common ground
Ground
*)
1
3
2
4
24
V
0 V
24 V
0 V
Load
Load
Load
Load
X31