5 Technical Data
40
Jetter AG
Braking relay
V
max
= DC 30 V
I
max
= DC 2 A
Contact: Type NO
connected to BR1 and BR2 on X10
The lines may only be connected to
devices that are related to the same
potential as the power supply of the
controller logic.
Can be switched by the control program of
PLC or by operating system of JetMove
208-480 together with software enable.
Digital Outputs
Number of outputs
Type of outputs
Rated voltage
Voltage range
Load current
Electrical isolation
Protective circuit
Protection against inductive loads
Signal voltage ON
4
Transistor pnp type
24 V
20 ... 30 V related to the ground potential of
voltage supply of processor logics
max. 0.5 A / output
None
Short-circuit, overload, overvoltage,
overtemperature protection
Yes
Type V
supply
- 1.5 V
Power dissipation P
v
Output stage: 125 W max.
Logic circuit: 20 W max.
Electrical Specifications
Summary of Contents for JetMove 208-480
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...3 Operating Conditions 34 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 90: ...10 Connection Diagrams 88 Jetter AG...
Page 100: ...13 Safe Torque OFF STO Option S1 98 Jetter AG...
Page 110: ...15 Ordering Information 108 Jetter AG...
Page 112: ...Appendices 110 Jetter AG...
Page 113: ...JetMove 208 480 Appendices Jetter AG 111 Appendices...
Page 114: ...Appendices 112 Jetter AG...
Page 122: ...Appendices 120 Jetter AG...