JetMove 208-480
5.1 Electrical Specification
Jetter AG
37
5
Technical Data
5.1
Electrical Specification
DANGER
Danger in the event that the Electrical Specification for the
"Safe Torque Off (STO)" option of the JM-2xx-xxx...-S1 amplifiers
are not complied with.
Dangerous injuries can occur!
For example from
• electric shock because the electrical safety has been violated by not observing
the degree of pollution;
• crushing if the functionality of the safety function STO is not ensured.
Make sure that the following electrical specifications are met.
Electrical Specifications
Rated voltage supply
• 3-phase direct supply
V
rms
= 3x400/480 V
Voltage asymmetry 2 % max. (voltage
dips 10 ms max. at continuous output)
• 48 ... 62 Hz
(frequency change 2 % / s max.)
Power supply tolerance
U
eff
= 340 V ... 528 V (-15 % ... +10 %)
Inrush current limitation
<10 A limited to < 500 ms during the
switch-on-sequence
Summary of Contents for JetMove 208-480
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...3 Operating Conditions 34 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 90: ...10 Connection Diagrams 88 Jetter AG...
Page 100: ...13 Safe Torque OFF STO Option S1 98 Jetter AG...
Page 110: ...15 Ordering Information 108 Jetter AG...
Page 112: ...Appendices 110 Jetter AG...
Page 113: ...JetMove 208 480 Appendices Jetter AG 111 Appendices...
Page 114: ...Appendices 112 Jetter AG...
Page 122: ...Appendices 120 Jetter AG...