9 Diagnostics
84
Jetter AG
9.2
Alarms
If the dot in the display is flashing, one or several alarms have been recognized.
Please check in the motion setup or by issuing the motion commands in the PLC
program which alarm has been activated.
F 45
Communication
error
CAN controller is in
Bus OFF state.
The error counter
value has reached
255.
– Stop with
emergency
stop ramp
– Check the
communication
connection
F 46
Communication
error
A smart encoder
(EnDat 2.2) may
have sent an error
message
– Immediate
motor power
disable
– Check the parameters
– Check the encoder
Fault Message Table JetMove 208-480
Fault
Number
Type of Fault
Description
Response to
Faults
Troubleshooting