2 Installing the JetMove 208-480
28
Jetter AG
2.6
Safety Instructions for
Commissioning
2.7
Notes on decommissioning
DANGER
Hazard caused by high operating voltage and electric
shock!
Extremely hazardous voltages of up to 850 V may occur!
Please observe the following precautions in order to avoid muscle cramps, burns,
unconsciousness, respiratory standstill, etc., and death:
Have commissioning jobs carried out by qualified personnel only, see
chapter 1.1.3 "Qualified Personnel", page 12.
Prior to commissioning, please do the following:
Reattach dismantled protective equipment and check it for proper
functioning.
By doing so, you will prevent accidents resulting from moving parts.
Secure the servo amplifier JetMove 208-480 against accidental contact
with conductive parts and components.
Only connect devices or electrical components to the signal lines of the
digital servo amplifier JetMove 208-480 (Enable, Limit+/-, REF, BRAKE 1
and BRAKE 2) that have been sufficiently isolated against the connected
electric circuits. These signal lines may only be connected with units that
have got the ground potential of the DC 24 V power supply.
The digital servo amplifier JetMove 208-480 has got a leakage current
greater than 3.5 mA. In order to avoid electric shocks, a second protective
earth conductor will be required.
For this, the measures listed in chapter 1.2.3 "Earthing Procedure", page
14 must be taken.
Each commissioning, even a short functional test, must always be carried
out with a PE (GND) bus correctly connected.
Before returning the device, remove the cable strap serving as strain relief
and motor cable shield.
Summary of Contents for JetMove 208-480
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...3 Operating Conditions 34 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 90: ...10 Connection Diagrams 88 Jetter AG...
Page 100: ...13 Safe Torque OFF STO Option S1 98 Jetter AG...
Page 110: ...15 Ordering Information 108 Jetter AG...
Page 112: ...Appendices 110 Jetter AG...
Page 113: ...JetMove 208 480 Appendices Jetter AG 111 Appendices...
Page 114: ...Appendices 112 Jetter AG...
Page 122: ...Appendices 120 Jetter AG...