INSTALLATION MANUAL
ZPS-
K5.3,
K10.3, K20.3 CLAMPING
MODULE WITH SENSOR
MONITORING, MOUNTING FLANGE
877.426.2504
SUBJECT TO TECHNICAL CHANGES.
JERGENS INC. · PHONE: 216.486.5540 · FAX: 216.481.6193 /553720 / 553721/
16
3.4
Installation of the clamping module in the mounting flange
Tilt-free insertion
Uniform insertion of 4 opposing
cylinder screws (2), up to flat
contact
.
The threaded pins (3) must not be screwed in too far, or the cover
cannot lie flat.
CAUTION: The spring is pre-tensioned during mounting
.
Uniform
tightening of the cylinder screws (2) to torque:
K5.3: (M4) 2.9 Nm
K10
.3
: (M
6
)
8.0
Nm
K20
.3
: (M6) 8
.0
Nm
After installation, the balls must be able to move freely in the track