Operating instructions
HMCflex
15/23
© ehb errors and omissions excepted
4 Explanations of the adjustable parameters
[1] Settings
Parameters
Explanations
[1] language
language
You can choose between German, English, French and Spanish
[2] sensors
temperature
The HMCflex can be factory set for the usual types of temperature sensor. The
type of temperature monitoring is programmed under [10] Inputs/Outputs.
oil pressure
The HMCflex can be factory set for the usual types of oil pressure sensor. The
type of oil pressure monitoring is programmed under [10] Inputs/Outputs.
pulse/revolution
The number of pulses from the pulse generator or the number of pole pairs on
the alternator must be stored here. With regard to this, see point 4 further set-
tings and explanations.
[3]
output
ETR-PullCoil
Type of operating magnet, setting for pull coil:
Operating magnet ETR:
An operating magnet (ETR - energise to run) means
a lifting magnet, which enables the flow of fuel when voltage is applied and
which must remain energised during operation of the engine.
Switch-off magnet ETS:
A switch-off magnet (ETS - energise to stop) means
a lifting magnet, which requires voltage to stop the engine.
None:
Magnet without pull coil
ETR-HoldCoil
Type of operating magnet, setting for hold coil:
Operating magnet ETR:
An operating magnet (ETR - energise to run) means
a lifting magnet, which enables the flow of fuel when voltage is applied and
which must remain energised during operation of the engine.
Switch-off magnet ETS:
A switch-off magnet (ETS - energise to stop) means
a lifting magnet, which requires voltage to stop the engine.
None:
The operating magnet is switched via the HMCflex
PIN 11
Alarm output or speed regulation magnet with Options options: setting for the
pull coil. You can choose between ETR (energised to run), ETS (energised to
stop), None
speed-holdCoil
Type of speed adjustment magnet, setting for the hold coil: you can choose
between ETR (energised to run), ETS (energised to stop), None
Speed time 1
Time period after start-up, after the speed adjustment magnet becomes active.
Settings between 1 and 99 seconds can be programmed.
CDowntime
Setting for the engine's cool down time. Settings between 0 and 15 minutes are
possible.
Summary of Contents for A540 Di D-1703 EDR 80km/h
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 44: ......
Page 46: ......
Page 71: ...Service Schedule...
Page 75: ...Original Ersatzteile Original spare parts Pi ces de rechange d origine...
Page 78: ......
Page 80: ......
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 90: ......
Page 92: ......