Fault Nb. 6 - Pressurization Pump Malfunction
Description :
Thermal failure of the pressurization pump used to increase suction line pressure in front of the feed
water pump (Speck pump).
Pressurization Pump
Hydrometer
Pompa Termiği
Fault Code Indicator
Solution
:
* Install the pressurization pump thermal inside the electrical control panel. The thermal is installed by pressing the
blue button as shown in the picture.
* Make sure the motor of the pressurization pump is functioning.
* Check the thermal amperage setting according to the pump motor amperage value.
* Check whether the electrical current to the pump is at sufficient voltage.
44
Summary of Contents for SHS Series
Page 10: ...Steam Distribution Connection Diagram 10 Buhar Da l m Kollekt r...
Page 12: ...Condensate Return Connection Diagram 12...
Page 15: ...15 Vent Connection and Blowdown Connection Diagram...
Page 55: ...55...
Page 56: ...56...