3-14
Maxor User’s Manual
www.javad.com
3
S E T U P A N D S U R V E Y
Surveying with the Maxor
–Enable Averaged and enter the Averaged Span in seconds, then click
Apply
.
Click
Tools->Reset receiver
and wait until the specified interval (span)
completes. Examine the Base coordinates on the Base tab, they should correspond
to the coordinates obtained from the average. Click
Refresh
if the coordinates are
zeros.
Notice:
The reference geodetic coordinates you specify on this
tab relate to the antenna L1 phase center.
Figure 3-11. Base Tab Configuration
11.
Select the
Ports
tab and set the following port parameters (Figure 3-12 on page 3-
15). Use serial port C for an internal PDL and GSM modem.
•
Output drop-down list – select type and format of differential corrections.
•
Period (sec) – enter interval at which receiver will generate differential
corrections.
•
Baud rate drop-down list – select a baud rate (i.e., the rate at which differential
messages will be transmitted from receiver to modem).
Summary of Contents for Maxor
Page 1: ...Maxor GNSS Receiver User s Manual Copyright Javad Navigation Systems Inc March 2004...
Page 2: ......
Page 8: ...VI Maxor User s Manual www javad com Notes...
Page 12: ...X Maxor User s Manual www javad com LIST OF FIGURES RS 232C Connector B 10 USB Connector B 11...
Page 20: ...XVIII Maxor User s Manual www javad com Notes...
Page 70: ...2 36 Maxor User s Manual www javad com Notes...
Page 138: ...E 2 Maxor User s Manual www javad com Notes...
Page 142: ...Index Maxor User s Manual www javad com Notes...