instALLAtiOn instRuctiOns (cont.)
NOTe: The load neutral terminal is not
used. There should be no connection
to the load neutral terminal on the GFCI
circuit breaker. The green wire (GND-
GReeN) is the equipment ground and
should be connected to the neutral bus
found in the main breaker box.
Figure 4
Figure 4A
Figure 4B
L2-WHITE WITH
RED MARK
L1-BLACK
GND-GREEN
FROM HEATER
FROM CONTROL(S)
L2
240 V
L1
NO CONNECTION
(LOAD NEUTRAL)
BREAKER BOX
Note: The load neutral terminal is not used. There should be no connection to the load neutral
terminal on the GFCI circuit breaker. The green wire (GND-GREEN) is the equipment ground
and should be connected to the neutral bus found in the main breaker box.
BREAKER BOX CONNECTIONS