Jason International, Inc. •
501.771.4477
Page 11 of 18
Customer Service : 800.255.5766
Copyright © 2011 Jason International.
Figure 5A
Figure 6A
Control box ConneCtions (ls640)
stAnDARD EDitiOn WHiRLpOOL pARts List
(Ls640)
Main/Secondary Pump
Keypad Cable
Pump Control Box
Control Box Stand
Keypad
Water Level Sensor
pREmiER EDitiOn WHiRLpOOL pARts List
(Ls640)
Main/Secondary Pump Pump Control Box
Keypad
Keypad Cable
Control Box Stand
LED Light Assembly
Ozone Sanitation Unit LED Light Cable
Water Level Sensor
stAnDArD eDition whirlpool
premier eDition whirlpool
Jason’s Standard Edition Whirlpool system features the best
in luxury bathing for the leisure bath industry. To assure that
your bath functions properly, the blower and pump control
boxes must be properly connected.
NOTe:
For 120v systems, the power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit.
tHE pump cOntROL BOX
The Pumps, keypad and Water Level Sensor must be plugged
into the proper receptacles for correct operation of the system.
See
Figure 5A
for connections: (A) The power cord for the
pump control box must be plugged into a 120, 20 amp, GFCI
dedicated circuit. (C) The pump’s power cord will need to
be plugged into the control box (B). (D) Two-pin terminal for
installation of the water sensor to the pump control box. (E)
8-pin mini-DIN terminal for the Whirlpool keypad.
Jason’s Premier Edition Whirlpool system incorporates all
the features of the Standard Edition system and includes
the benefits of a combination pump/heater, ozone sanitation
system, and an LED Chromatherapy light. To assure that
your bath functions properly, the pump control box must be
properly connected.
NOTe:
For 120v systems, the power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit.
tHE pump cOntROL BOX
The Pumps, keypad and Water Level Sensor must be plugged
into the proper receptacles for correct operation of the system.
See Figure 6A for connections: (A) The power cord for the
pump control box must be plugged into a 120, 20 amp, GFCI
dedicated circuit. (C) The pump’s power cord will need to
be plugged into the control box (B). (D) Two-pin terminal for
installation of the water sensor to the pump control box. (E)
8-pin mini-DIN terminal for the Whirlpool keypad. (F) 6-pin
mini-DIN terminal for the Led light.
Note:
This diagram (Figure 5A) also applies to 50 Hz,
240v controls, and power supply systems. Except that the
Whirlpool pump junction box must be connected into one
dedicated 240v, 20 Amp GFCI circuit.
Note:
This diagram
(Figure 6A)
also applies to 50 Hz, 240v
pumps, controls, and power supply systems. Except that
the Whirlpool pump junction box must be connected into