RTU mode
:
START
Keep that zero
-
input signal is more than or equal to 10 ms
Address
Communication address
:
8
-
bit binary address
Function
Function code
:
8
-
bit binary address
DATA
(
n
-
1
)
Data characters
:
n x 8
-
bit data
,
n
=
16
DATA0
CRC CHK Low
CRC Check
:
CRC CHK High
16
-
bit CRC Check consists of 2 8
-
bit binary systems
END
Keep that zero
-
input signal is more than or equal to 10 ms
Communication Address
00H
:
All driver Broadcasts
01H
:
For inverter with 01st address
OFH
:
For inverter with 15th address
10H
:
For inverter with 16th address
,
by analogy
,
the maximum could reach 240
.
Function code and Data Characters
03H
:
Read out the content of temporary storage
06H
:
Write a WORD into temporary storage
;
Function code 03H
:
Read out the content of temporary storage
.
For example
:
Driver address 01H
,
reads out the data characters in 2 successive
temporary storages as follows
:
Initial temporary storage address 2102H
Function code 06H
:
Write a WORD into temporary storage
.
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul