66
17
:
Coasting stop
When this terminal is valid
,
inverter coasting to stop
.
18
.
Fault reset
Reset the inverter when alarm occurs
,
this terminal function is sameto that of
the RESET key on the Keypad
.
19
.
PID function enable
When this contact closes
,
PID function is enabled
.
When P601 is set as 2
,
PID is
invalid when this contact is disconnected
.
20
.
PLC function enable
When this contact closes
,
PLC function starts up
,
and corresponding PLC
function opens
.
21
.
Timer 1 starts up
22
.
Timer 2 starts up
When this contact closes
,
timer starts up and begins timing
,
when the timer
reaches set value
,
corresponding multifunction output contacting action
.
23
.
Counter pulse input
This terminal may accept pulse signals of no more than 250 Hz
.
24
.
Counter resetting
The counted values may be reset and cleared through this terminal
.
19
.
PLC memory removal
In the running process of PLC program
,
owing to fault or stopping
,
inverter will
record status of the program automatically
,
after the fault is cured and the
inverter is switched on again
,
the inverter will continue running according to the
program
,
when memory removal is valid
,
program may be reset
,
and inverter
operates from the beginning
.
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul
Summary of Contents for FC100 Series
Page 9: ...9 Chapter 2 Storage and Installation ...
Page 12: ...12 ...
Page 13: ...13 Chapter 3 Wiring Diagram and Terminal Explanation ...
Page 20: ...20 ...
Page 21: ...21 Chapter 4 Keypad Operation ...
Page 24: ...24 4 ...
Page 25: ...25 Chapter 5 Function Parameters Table ...
Page 36: ...36 ...
Page 37: ...37 Chapter 6 DESCRIPTION OF PARAMETER SETTINGS ...