Page 6
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual
table 1. Jandy
p
ro
s
eries JE Heat
p
ump
technical
s
pecifications
M
od
E
l
JE1500
t
JE2000
t
JE2500
t
JE
25
00
t-
3
JE3000
t
JE3000
tr
JE
30
00
t
3
JE
30
00
t
r
3
VOLTAGE
23
0V
/6
0H
Z
23
0V
/6
0H
Z
23
0V
/6
0H
Z
20
8/
23
0V
/6
0H
Z
/3
23
0V
/6
0H
Z
20
8/
23
0V
/6
0H
Z
/3
OUTPUT*
72
,0
00
B
T
U
s
108,000 BTUs
119,000 BTUs
137,000 BTUs
INPUT*
3.
83
k
W
5.03 kW
5.34 kW
6.37 kW
COP*
5.5
6
6.2
6.3
OUTPUT, STANDARD RATING CONDITIONS**
67,000 BTUs
92,000 BTUs
106,000 BTUs
127,000 BTUs
COP, STANDARD RATING CONDITIONS**
5.2
5.7
5.6
6.0
5.9
6.0
5.9
OUTPUT, LOW AMBIENT**
46,000 BTUs
64,000 BTUs
74,000 BTUs
86,000 BTUs
86,000 BTUs
COP, LOW AMBIENT**
4.0
4.0
4.0
4.2
4.0
4.2
4.0
RLA (RUNNING LOAD AMPS)
19.87A
30.77A
32.05A
23.21A
32.05A
25.00A
LRA (LOCKED ROTOR AMPS)
105A
178A
148A
164A
185A
164A
MINIMUM CIRCUIT AMPACITY
26.14A
40.21A
41.81A
30.76A
41.81A
33.0A
MAX OVER CURRENT PROTECTION***
45A
60A
60A
45A
60A
50A
HEAT EXCHANGER
Titanium
COMPRESSOR
Reciprocating
Scroll
Scroll
Scroll
CABINET
ABS
REFRIGERANT
64 Oz, R410A
78 Oz, R410A
78 Oz, R410A
78 Oz, R410A
118 Oz, R410A
126 Oz, R410A
118 Oz, R410A
126 Oz, R410A
R
E
F
R
IG
E
R
A
N
T
H
IG
H
P
R
E
S
S
U
R
E
A
LA
R
M
600 PSI (reset to 460 PSI)
R
E
F
R
IG
E
R
A
N
T
L
O
W
P
R
E
S
S
U
R
E
A
LA
R
M
-
H
E
A
T
IN
G
U
N
IT
S
58 PSI (reset to 127 PSI)
R
E
F
R
IG
E
R
A
N
T
L
O
W
P
R
E
S
S
U
R
E
A
LA
R
M
-
R
E
V
E
R
S
E
U
N
IT
S
35 PSI (reset to 74 PSI)
LOW WATER FLOW ALARM
20 GPM
MAXIMUM HEIGHT BELOW WATER LEVEL
10 feet below pool level
MINIMUM HEIGHT ABOVE WATER LEVEL
5 feet above pool level
OPTIMAL WATER FLOW
30 GPM
42 GPM
48 GPM
48 GPM
57 GPM
57 GPM
MINIMUM WATER FLOW
20 GPM
MAXIMUM WATER FLOW
70 GPM
AIR FLOW
2100 CFM
3600 CFM
WATER TEMPERATURE DIFFERENTIAL (DELTA
T)
Adjustable between 1
°F to 5
°F
UNION SIZE
2”
WEIGHT
175 lbs
220 lbs
223 lbs
223 lbs
228 lbs
230 lbs
228 lbs
230 lbs
*
Test Conditions: 80
˚ F
Air
, 80% RH, 80
˚ F W
ater
, Outside the scope of
AHRI Standard 1
160 (I-P)
** Rated in accordance with
AHRI Standard 1
160 (I-P)
*** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest standard size breaker
.
The breaker size must not be smaller than the Minimum Circuit
Ampacity value.
Summary of Contents for JE