Page 19
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual
spa Mode - (normal Heat)
To enable the spa mode, press
spa
. The associated left
green LED indicator will light and the unit will display
sEt:xxx°
.
notE
XXX
represents the current temperature setting
on the control. The default setting for spa
temperature is 102°F (38°C).
You can change the temperature set point by pressing
the
up
or
down
button
.
Repeatedly press the
up
or
down
button until you reach the desired temperature
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature falls
to 1 degree below the temperature setting
and
after a 5
minute delay, the control will start the heat pump and
the associated right LED will light RED.
spa Mode - (optional Maintain Heat)
If connected to an AquaLink, the Maintain Heat mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
notE
This feature only works when connected to
an AquaLink
.
To operate in spa mode with the Maintain Heat feature,
press
spa
, then press
MEnu
,
press the
down
button
until
Maintain spa HEat
is displayed, press the
MEnu
button. The associated left green LED indicator
will light and the unit will display
sEt:xxx°
.
Change
the temperature set point by pressing the
up
or
down
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
5.3
operating Features of Hybrid units
with optional Chiller
notE
The chiller is an optional equipment. Not all
units are provided with chiller
.
pool Mode - (normal Chill)
To enable the pool mode, press
pool
. The associated
left green LED indicator will light and the unit will
display
sEt:xxx°
.
notE
XXX
represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
Press the
MEnu
button. P
ress the
up
or
down
button
until you reach
pool CHill
, press the
MEnu
button.
notE
pool CHill
will not be displayed if the unit is
not provided with chiller.
You can change the temperature set point by pressing
the
up
or
down
button
.
Repeatedly press the
up
or
down
button until you reach the desired temperature
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature rises
to 1 degree above the temperature setting
and
after a 5
minute delay, the control will start the heat pump and
the associated right LED will light GREEN
.
pool Mode - (optional Maintain Chill)
If connected to an AquaLink, the Maintain Chill option
mode allows the unit to monitor the temperature of the
water 24 hours a day by turning the pool pump on and
sampling the water temperature.
notE
This feature only works when connected to
an AquaLink
.
When the temperature of the water rises above the
desired temperature setting, the control will then turn on
the unit and the associated right green LED will light.
To operate in pool mode with the Maintain Chill feature,
press
pool
, then press
MEnu
, then press the
down
button until
Maintain pool CHill
is displayed,
press the
MEnu
button. The associated left green LED
indicator will light and the unit will display
sEt:xxx°
.
Change the temperature set point by pressing the
up
or
down
button until the desired set point is displayed.
After 5 seconds of inactivity, the new set point is stored
in memory.
spa Mode - (optional Maintain Chill)
If connected to an AquaLink, the Maintain Chill mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
notE
This feature only works when connected to
an AquaLink
.
When the water temperature rises above the
programmed temperature set point, the control will start
the heat pump.
To operate in the spa mode with the Maintain Chill
feature, press
spa
, then press
MEnu
, press the
down
button until
Maintain spa CHill
is displayed,
press the
MEnu
button. The associated left green LED
indicator will light and the unit will display
sEt:xxx°
.
Change the temperature set point by pressing the
up
or
down
button until the desired set point is reached.
After 5 seconds of inactivity, the new set point is stored
in memory.
Summary of Contents for JE
Page 2: ......
Page 4: ...Page 2 ENGLISH Jandy Pro Series JE Heat Pumps Installation and Operation Manual...
Page 34: ......
Page 36: ...Page 2 fran ais Thermopompes Jandy Pro de la s rie JE Manuel d installation et mode d emploi...
Page 66: ......
Page 68: ...P gina 2 ESPA OL Bombas de calor Jandy Pro serie JE Manual de Instalaci n y Operaci n...