Appendix 73
RMC-675/RMC-673
8.3.80
SHP Level
Function
Command String
Camera Response
Set SHP Level
:SHP=[DD]<cr> :o<cr>
Set the SHP level. [DD] is the level value with a range of 0-47.
This command applies only to camera models TM-770, RMC-
673, and RMC-675.
Get SHP Level
:SHP?<cr> :oSHP[DD]<cr>
Enquire current SHP level. [DD] is the current value with a
range of 0-47. This command applies only to camera models
TM-770, RMC-673, and RMC-675.
8.3.81
Shutter Enable
Function
Command String
Camera Response
Shutter Enable
:SHE=[D]<cr> :o<cr>
Enables or disables electronic shutter control. [D] controls the
shutter state:
0 = Shutter control disabled.
1 = Shutter control enabled.
Get Shutter Enable State
:SHE?<cr> :oSHE[D]<cr>
Enquire current shutter control enable state. [D] is the current
shutter state:
0 = Shutter control disabled.
1 = Shutter control enabled.
8.3.82
Shutter Speed
Function
Command String
Camera Response
Set Shutter Speed
:SHS=[DDD]<cr> :o<cr>
Set the integration time (shutter speed) in units of one
horizontal line. [DDD] is the speed with a range of 1-260. One
line is equivalent to 63.56 usec.
Get Shutter Speed
:SHS?<cr> :oSHS[DDD]<cr>
Enquire current shutter speed. [DDD] is the current value in
lines with a range of 1-260. One line is equivalent to 63.56
usec.
8.3.83
Sharpening Threshold - SHT
Function
Command String
Camera Response
Set Sharpening Threshold
:SHT=[DDD]<cr> :o<cr>
Set the advanced color sharpening threshold value. [DDD] is
the value with a range of 0-127. This command applies only to
camera models RMC-673 and RMC-675.
Get Sharpening Threshold
:SHT?<cr> :oSHT[DDD]<cr>
Enquire current sharpening threshold value. [DDD] is the
current value with a range of 0-127. This command applies
only to camera models RMC-673 and RMC-675.