Figure 8.
Vertical timing details for interlaced. PAL
3.2.2
Integrate Mode
The standard factory setting for the RMC-675/RMC-673 camera is FIELD MODE.
An External Integrate mode is located on pin 12 of the 15 pin connector. This allows frames to continually
integrate until this input pin is released. This is normally high or open. Holding the input “low” starts the integration.
To use this mode:
Input:
Ext. trigger to pin 12 on 15 pin connector.
Set MFI mode: “VD mode”
Set MFI Termination: “Hi Z”
3.2.3
Vertical Mode
The standard factory setting for the RMC-675/RMC-673 camera is FIELD MODE.
In Field Mode, two horizontal rows are scanned together, changing the pair at each interlace scan.
3.2.4
External Trigger
External Trigger functions are not supported.