User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 106 -
Note:
You can reset a specific counter's count value by executing CounterReset[Counter0,
Counter1, Counter2, Counter3].
Internal Camera Blocks
To Use the Counter Function
Configure the settings as follows.
Four counters are available. Specify a counter (Counter0 to Counter3), and configure the settings.
Item
Setting Value
Selectable Range
Description
Counter 0
~
3
Counter 0
~
3
Select the counter.
CounterEventSource
Counter0: Off, Frame Trigger
Counter1: Off, ExposureStart
Counter2: Off, SensorReadOut
Counter3: Off,
FrameTransferEnd
Select the Counter Event signal for which to
read the count value.
When set to Off, the counter operation will
stop (but will not be reset).
CounterEventActivation
When the Counter function is
enabled:
Counter0, Counter1, Counter2 =
RisingEdge (Fixed)
Counter3 = FallingEdge (Fixed)
Specify timing at which to count.