User Manual (Ver. 1.0) - Setting List
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 144 -
Sequencer Control Item
Setting
Range
Default
Value
Description
SequencerOffsetY
-
0
Set the vertical offset value for the selected SequencerIndex.
Setting Range: 0
~
[Height - Height], Step 2(1)*
*For monochrome models, when BinningVertical = 2, the value in
parentheses is applicable.
SequencerFrameCount
1
~
65535
1
Set the FrameCount value for the selected SequencerIndex.
Note:
The same value with AcquisitionFrameCount (
SequencerExposureTime
1
~
8000000
-
Set the exposure time for the selected SequencerIndex.
Default
: ExposureTimeMax (
SequencerGainAnalogAll
1.0
~
126.0
1
Set the Gain[AnalogAll] value for the selected SequencerIndex.
Note:
The same value with Gain[AnalogAll] (
)
SequencerGainDigitalRed
0.447
~
5.624
1
Set the Gain[DigitalRed] value for the selected SequencerIndex.
Note:
The same value with Gain[DigitalRed] (
). Color models
only.
SequencerGainDigitalBlue
0.447
~
5.624
1
Set the Gain[DigitalBlue] value for the selected SequencerIndex.
Note:
The same value with Gain[DigitalBlue] (
). Color models
only.
SequencerLUTEnable
0: False
1: True
0: False
Set the LutEnable value for the selected SequencerIndex.
SequencerSetNext
0
~
32
-
Set the next index to be displayed for the selected SequencerIndex.
(Enabled only for TriggerSequencer.) If 0 is specified, the operation of the
Sequencer is stopped.
SequencerSetSelector = 1
~
31: (SequencerSetS1)
SequencerSetSelector = 32: 1
SequencerRepetition
1
~
255
1
Set the repeat count for the sequencer.
SequencerSetActive
1
~
32
1
Displays the active index number.
SequencerSetStart
1
~
32
1
Specify the first index number to switch to when starting
TriggerSequencerMode.
SequencerCommandIndex
1
~
32
1
Set this to change the SequencerIndex. (Enabled only for
CommandSequencer.)
SequencerReset
-
-
In TriggerSequencerMode, reset the current index number to the number
configured in SequencerSetStart.