User Manual (Ver. 1.0) - Setting List
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 134 -
Pulse Generator Item
Setting Range
Default Value
Description
PulseGeneratorEndPointMs
(ms)
-
50
Set the start point of the Low interval in milliseconds. When
the counter reaches this value, the output will be 0. The
setting range varies depending on the ClockPreScaler
value.
PulseGeneratorEndPointMs = 1/PulseGeneratorClock *
PulseGeneratorEndPoint
PulseGeneratorPulseWidth
(ms)
-
50
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is
calculated. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorPulseWidth = 1/PulseGeneratorClock *
(PulseGeneratorEndPoint - PulseGeneratorStartPoint)
PulseGeneratorRepeat
Count
0
~
255
0
Set the repeat count for the counter. When this is set to 0, a
free counter is enabled with no repeat limit.
PulseGeneratorClear
Activation
0: Off
1: Rising Edge
2: Falling Edge
3: Level High
4: Level Low
0: Off
Set the clear signal condition for the count clear input of the
pulse generator.
PulseGeneratorClear
Source
-
24: Line5 Opt In1
Select the count clear input signal source.
1: AcquisitionActive
2: FrameActive
4: ExposureActive
5: FVAL
7-10: PulseGenerator0-3(
※
)
11-14: UserOutput0-3
24: Line5 Opt In1
36: Nand0 Out
37: Nand1 Out
43: AcquisitionTriggerWait
44: FrameTriggerWait
Note:
(
※
)Disabled if the PulseGenerator is selected in
PUlseGeneratorSelector.
PulseGeneratorClear
SyncMode
0:Async Mode
1:Sync Mode
0:Async Mode
Select the sync mode for the count clear input signal.