User Manual (Ver. 1.0) - Preparation
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 27 -
Step 5: Change the Camera Settings
This section explains how to change settings by describing the procedure for changing the output
format as an example.
Configure the Output Format
Configure the size, position, and pixel format of the images to be acquired. The factory settings are as
follows. Change the settings as necessary.
Factory default values (GOX-16205C-PGE)
Item
Default Value
ImageFormatControl
Width
5328
Height
3040
OffsetX
0
OffsetY
0
PixelFormat
BayerRG8
Note:
You can specify the image acquisition area. For details, see “
”.
Example: Configure the Width of ImageFormatControl
1. By selecting the item of Width, you can change the value as shown below.
Note:
Depending on the setting item, you need to change visibility. Please switch visibility
(Beginner / Expert / Guru) as necessary.