AD-130GE
65
(3)
Last Sequence
:
(applicable value
:
1
~
10)
To determine how many sequences out of sequences 1 to 10 are executed as one
consecutive sequence.
(4)
Sequence Selector
:
In the Sequence Selector, there are 10 sequence tables.
Each Sequence has 8 setting parameters such as Sequence ROI Size X and Y
、
Sequence ROI Offset
X and Y
、
Sequence Exposure Raw
、
Sequence Master Gain Raw
、
and Repeat Count in Each Step.
In the Sequential EPS
Trigger, the order to execute is from Sequence 1 settings.
(5)
Repeat Count in Each Step
:
(applicable value
:
1
~
255)
After the Sequence table is repeated as many as numbers set in ―Repeat Count in Each
Step
”
, the next sequence table is activated.
(6)
Reset Sequence command
:
If the Reset Sequence is applied during sequence operation, the sequence operation is
initialized to start at sequence 1.
(7)
Sequence Table Reset input:
The Sequence Table Reset is available from GPIO output port.
This initializes the sequence operation by hardware trigger.
The following is how the settings appear in the GUI.