AD-130GE
36
8.4. Video timing
8.4.1 Horizontal Timing
The horizontal timing for Continuous mode, full frame and partial scan are shown below.
This is common for both Bayer color imager and monochrome IR imager.
1 Clock =51.324MHz (19.48ns)
1CLK: 1 Pixel clock period
OB:
Optical black
LVAL is HIGH in the period of optical black and effective video periods
DVAL is HIGH in the effective video period
Fig.27 Horizontal Timing