AD-130GE
55
10.5.2 Continuous mode
For applications not requiring asynchronous external triggering, this mode should be used for
continuous operation.
To use this mode
Set function:
Acquisition mode
:
Continuous
Trigger mode
:
OFF
Sync mode
:
Sync / Async
Exposure Mode
:
Timed
Pixel Format
:
8bit
、
10bit
、
12bit
Other functions
10.5.3 Edge Pre-Select (EPS) trigger mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
the fixed shutter speed set by registers. The accumulation can be LVAL synchronous or LVAL
asynchronous. The resulting video signal will start to be read out after the selected shutter
time.
To use this mode:
Set function:
Acquisition mode
:
Frame Start
Trigger mode
:
ON
Sync mode
:
Sync / Async
Exposure Mode
:
Timed
Exposure time
:
Exposure time/Exposure time(us)/
Exposure time(Raw)
Other functions
Input:
External Trigger
Trigger Source
This function can be set by selecting Edge pre-select in Exposure mode of JAI Acquisition Control.
However, Acqusition Mode,
Sync Mode,
Exposure Time, and so on should be set.