AD-130GE
58
Note: 2.8L after the exposure end of the longest exposure
Fig.36 Edge Pre-select LVAL synchronous
t1(Exposure start delay)
t2
t3(Data output delay)
0.1L
~
1.1L(3
~
35.2
μ
s)
2.8L
10.8L
Fig.37 Edge Pre-select LVAL synchronous details
Note for setting Exposure Time
For instance, if the exposure time for the color channel is 1/31 sec and that of the monochrome
IR channel is 1/87,000 sec, the picture quality of the monochrome IR channel may not be
acceptable due to CCD’s operational principle. Accordingly, in EPS mode, each channel’s
exposure time should be set the same. If it is necessary to set different exposure times, please
confirm the picture quality in advance of usage.
DATA out
Ext.Tri g
FVAL
EEN
LVAL
Exposure
Exposure Period
t1
t2
t3