52
J-300
14.3 Panel Displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Water temperature is below
55°F (12.78°C). Jets Pump 1, Jets Pump 2 and the circulation pump will
activate for 10 minutes, then turn off. Then the circulation pump and the
heater will activate for 10 minutes. The two cycles shall repeat until the
water temperature reaches 65°F (18.33°C). See “Winterizing” (page 45).
14.4 Panel Displays SN--1
Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not
functioning. Contact your authorized Jacuzzi dealer or qualified service
technician. The display will alternate between
“SN--1”,
scrolling
message
“HI-LIMIT SENSOR ERROR”
and the current water
temperature.
14.5 Panel Displays SN--2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Jacuzzi
dealer or qualified service technician. The display will alternate between
“SN--2”
and the current water temperature. The display will alternate
between
“SN--2”,
scrolling message
“WATER SENSOR ERROR”
and
the current water temperature.
14.6 Panel Displays Change CLEARRAY Bulb
The CLEAR
RAY
bulb timer has expired. UV bulb needs to be replaced.
The display will alternate between the current temperature reading and
the scrolling message
“CHANGE CLEARRAY BULB”
as long as the
error exists. The countdown timer for the UV bulb needs to be reset (page
35). A new UV bulb can be purchased from a local Jacuzzi dealer.
14.7 Panel Displays Change Filter
The filter change timer has expired. The spa filters need to be cleaned
or replaced. The display will alternate between the current temperature
reading and the scrolling message
“CHANGE FILTER”
as long as the
error exists. The countdown timer for the Change Filter feature needs to
be reset (page 35). New filters can be purchased from a local Jacuzzi
dealer.
14.8 Panel Displays Change Water
The water refresh timer has expired. The spa needs to be drained and
refilled. The display will alternate between the current temperature
reading and the scrolling message
“CHANGE WATER”
as long as the
error exists. The countdown timer for the Change Filter feature needs to
be reset (page 36). New filters can be purchased from a local Jacuzzi
dealer.
Summary of Contents for J - 375