14
J-300
Export Models (50 Hz) Service
Single Breaker
Service 1
(including Heater)*
Single Breaker
Service 1 (including
Heater)**
Voltage:
230 VAC
230 VAC
Max. Current Draw:
1-Pump System
15A
22A
2-Pump System
17A
29A
Wattage:
1-Pump System:
3.5 kW
5.1 kW
2-Pump System:
3.9 kW
6.7 kW
Frequency:
50 Hz
50 Hz
Number of Wires:
3
3
Single Breaker is the factory default.
*
For this service, the heater
will not operate
while either jets pump is
running. The service 1 breaker will include connection for all components.
** For this service, the heater
will operate
while two jets pump are running.
The service 1 breaker will include connection for all components.
Export Models (50 Hz) Service
Dual Breaker
Service 1/
Service 2***
Three Phase Service
Service 1/
Service 2/Service 3***
Voltage:
230 VAC
230 VAC
Max. Current Draw:
1-Pump System
12A/10A
N/A
2-Pump System
12A/17A
12A/10A/7A
Wattage:
1-Pump System:
2.8kW/2.3kW
N/A
2-Pump System:
2.8kW/3.9kW
2.8kW/2.3kW/1.6kW
Frequency:
50 Hz
50 Hz
Number of Wires:
5
5
Single Breaker is the factory default.
*** For this service, the heater
will operate
while two jets pump are running.
The service 1 breaker will include connections for the heater and
transformer. The service 2 breaker is for all other components.
**** In this configuration, the heater
will operate
while all jets pumps are
running. The service 1 breaker will include connections for the heater
and transformer. Service 2 breaker is for pump 1 and other components.
Service 3 breaker is for pump 2.