64
J-300
17.3 Single Service 50Hz Connection
Wiring for export models with a single service breaker. The jumper wiring
is shown below.
The included extra White wire (1*)
must
be installed.
17.4 Dual Service 50Hz Connection
Wiring for export models with dual service breakers. The jumper wiring is
shown below.
G-GRN
L1 BRN
N1 BLU
A
B
C
D
P1 2SPD
UV
A/V
30A (PMP 1)
30A (PMP 2)
J33
J36
J53
J41
J46
J47
J51
J59
J38
J44
J49
F4
F6
J35
J37
1*
2
4
3
ALL MODELS
Single Service Jumper Wiring
Wire
From
To
1*
J33
J47
2
J59
J41
3
J37
J36
4
J46
J51
*Extra connection must be
made
BREAKER TERMINAL
CONNECTIONS
L1 = All components
1
2
3
GRN
N2 BLU
L1 BRN
N1 BLU
L2 BRN
A
B
C
D
P1 2SPD
UV
A/V
30A (PMP 1)
30A (PMP 2)
J33
J36
J53
J41
J46
J47
J51
J59
J38
J44
J49
F4
F6
J35
J37
ALL MODELS
Dual Service Jumper Wiring
Wire
From
To
1
J33
J51
2
J59
J38
3
J37
J53
BREAKER TERMINAL
CONNECTIONS
L1 = Heater & Transformer
L2 = All other components
Summary of Contents for J - 375
Page 6: ...J 300...