Fastening the system to walls and floors
Mount the square plate (
✐
24, detail 1
) on the framework of
the fitted-out wall. Mark the hole on the wall, bore, and fasten the
square plate:
•
to the wall, by means of 1 screw and screw anchor;
•
to the framework, by means of 2 nuts (
✐
24, detail 3
).
Mount the other square plate (
✐
25
) on the opposite corner,
mark the hole, bore, and fasten the square plate:
•
to the wall, by means of 1 screw and screw anchor (
detail 2
);
•
to the upright of the wall with mirror, by means of 1 screw
(
detail 3
).
Re-assemble the sliding door (if you had disassembled it), fol-
lowing the indications given in Chapter “Completion and checks”.
Connect the drain to the floor drain for good.
Anchor the tub for good, by means of the screws supplied, using
the screw anchors you had previously inserted in the floor (
✐
1,
detail 3
).
Installation of front panel on tub
Fasten the 2 metal supports (
A
) to screw anchors (
B
) under the
tub rim (
✐
1, detail 4
).
Insert springs (
C
) (
✐
1, detail 5
) onto the props on the tub cor-
ners, make them slide up as far as they will go, and push them
sideways so as to cause them to be positioned inside the tub rim.
Insert ring (
D
) in the race of the prop.
Position square plates (
E
), respecting the indicated dimensions
(
✐
1, detail 6
), then lock them in position by means of nuts (
F
).
Move the panel towards the tub, and, pressing on the upper edge
of the panel, insert it between the central-lateral springs and the
tub rim (
✐
1, detail 7
).
Move the panel up, and align the holes in it with the slots on
the brackets.
Fasten the panel with 4 screws (
✐
1, detail 7
), and fit in the
caps supplied.
Electrical safety
Jacuzzi
®
hydromassage products are safe appliances, manufactured in
compliance with
EN 60335.2.60, EN 61000, EN 55014 and TS
2000/01
norms and are approved by the
TÜV Certifying Institute
.
Installation must be carried out by qualified and authorized person-
nel and must guarantee full compliance with the national regulations
in force.
It is the installer’s responsibility to select the materi-
als in relation to their use, to carry out the work cor-
rectly, and to check the condition of the network to
which the apparatus will be connected and its capa-
bility to ensure user safety.
The Flexa Twin shower enclosures are class “I” apparatus, and must
be anchored securely and connected permanently, without any inter-
mediate joints, to the electric network and ground system.
The electric network and ground system of the build-
ing must be in working order and must comply with
the provisions of the law and specific regulations in
force in that country.
For the connection to the electric network, it is necessary to install a
disconnecting multiple-pole switch, placing it in an area that complies
with safety prescriptions for bathrooms. The multiple-pole switch
must ensure a contact opening of at least 3 mm, and must be suitable
for a voltage of 220-240 V and a current up to 16 A.
The switch and electric devices, in compliance with
regulations, must be placed in an area that cannot be
reached by the person who is using the shower enclo-
sure.
The installation of electric devices and apparatus (sockets, switches,
etc.) in bathrooms must comply with the provisions of the law and regu-
lations in force in that country. In particular, the installation of any elec-
tric device is forbidden in the area surrounding the shower enclosure
for a distance of 60 cm and a height of 225 cm (
✐
30
).
For the connection to the electric network of the building, a cable
with sheath having characteristics not inferior to type
H 05 VV-F
3x2,5 mm
2
must be used.
The electric network of the building must be
equipped with a 0.03-A differential switch.
The FLEXA TWIN shower enclosures are equipped with a terminal,
fitted on the framework and marked with the symbol
, for the
equipotential connection of the surrounding metal masses, as laid
down by the EN 60335.2.60 standards.
JACUZZI EUROPE declines all responsibility in the following cases:
if the installation is performed by personnel not qualified and/or
not certified to perform the said installation.
if the provisions of the law and regulations relevant to the electric
networks of buildings, in force in the country in which the installa-
tion is performed, are not complied with;
if the instructions for installation and maintenance contained in
this manual are not followed;
if unsuitable and/or uncertified materials are used for the
installation;
if the installation of the Flexa Twin shower enclosures does not
comply with the regulations mentioned above;
if the installer performs incorrect operations that reduce the degree of
protection against water jets, change the protection against electrocu-
tion by direct or indirect contact, or generate conditions of abnormal
insulation, current dispersion or overheating;
if some components or portions of the equipment are replaced or mod-
ified with respect to the state in which they have been supplied, caus-
ing the manufacturer’s liability to become null and void;
Summary of Contents for FlexaTwin
Page 2: ......
Page 24: ...24 115 118 126 38 25 140 90 57 130 120 140 12 57 cm 8 mm 1 2 cm 90 90 2 4 5 3...
Page 25: ...25 1 2 TE M6 x 30 mm 6x18 mm O Ring 1 2 7 6...
Page 26: ...26 1 3 2 A 8 9...
Page 27: ...27 1 2 3 A A B B 1 2 M4x16 mm M4 4x16 mm 10 11...
Page 29: ...29 2 1 2 3 2 1 4 5 1 3 3 14 15...
Page 30: ...30 1 2 2 2 3 4 1 1 16 17...
Page 31: ...31 1 2 3 2 4 1 7 mm 18 19...
Page 32: ...32 3 2 4 1 7 mm 6 mm TE 4 2x32 mm 20 21...
Page 33: ...33 1 2 2 3 4 3 5x19 mm 4x9 mm 3 5x13 mm 3 mm 22 23...
Page 34: ...34 2 1 3 TE 4 2x32 mm M4 6 mm TE 4 2x32 mm 3 9x19 mm 6 mm 3 2 1 24 25...
Page 59: ...59...