07610-003-61-42-U
24
PROBLEM
POSSIBLE CAUSE
REMEDY
Dishmachine will not fill
after the door is close.
Power “ON” light is
illuminated.
1. Faulty rinse solenoid valve.
2. Faulty door switch.
3. Fouled/faulty high-level probe.
1. Repair or replace valve as required.
2. Verify the wiring of the switch; if correct, replace the
switch.
3. Clean probe if fouled. If clean, and still not working,
replace.
Dishmachine will not fill
after the door is closed.
Power “ON” light is
NOT illuminated.
1. Service breaker tripped.
2. Machine not connected to
power source.
3. Faulty power source.
1. Reset. If the breaker trips again, contact an electrician to
verify the amp draw of the machine.
2. Verify that the machine has been properly connected to
the power source.
3. Verify the wiring of the switch; if correct, replace switch.
Dishmachine will not
run after the door is
closed. Power “ON”
light is illuminated and
the unit is filling.
1. Timer is faulty.
2. Wash motor faulty/damaged.
3. Wash motor contactor faulty.
1. Check to see that the timer is receiving power. If so,
replace the timer assembly.
2. Verify that the wash motor is getting power. If so,
replace the motor.
3. Check for continuity; if contacts are open, replace the
contactor.
Dishmachine runs
continuously in the wash
cycle.
1. Machine is in Delime mode.
2. Timer motor is faulty.
3. Cam timer jammed by
obstruction.
1. Flip mode switch to AUTO.
2. Verify that the timer is rotating. If not, check to see that
the motor is receiving power. If so, replace the motor
and/or timer assembly.
3. Remove obstruction.
Wash or rinse heater
does not work
1. Faulty heater element.
2. Faulty heater contactor.
3. Misadjusted/faulty
thermostat(s).
1. Check element for continuity; if open, replace the heater.
2. Replace the contactor.
3. Verify operation and setting of thermostats, replace if
necessary.
Dishmachine fills slowly
and/or the rinse is
weak.
1. Clogged or obstructed rinse
arms.
2. Low incoming water pressure.
3. Y-strainer is clogged
1. Remove and clean the rinse arms.
2. Adjust the water pressure regulator to ensure that there
is 10 ± 2 PSI flow.
3. Clean out the Y-strainer.
Rinse water not
reaching required
temperature.
1. Faulty rinse heater.
2. Mis-adjusted/faulty
thermostat(s).
3. Rinse thermometer is
defective.
1. Check element for continuity; if open, replace heater.
2. Verify operation and setting of thermostats, replace if
necessary.
3. Replace thermometer.
WARNING:
Inspection, testing, and repair of electrical equipment should only be performed by a
qualified service technician. Many of the tests require that the unit have power to it and live electrical
components be exposed.
USE EXTREME CAUTION WHEN TESTING THE MACHINE.
!
WARNING
COMMON PROBLEMS
TROUBLESHOOTING
Summary of Contents for TEMPSTAR LT
Page 35: ...07610 003 61 42 U 28 26 1 29 28 30 33 34 36 CONTROL BOX ASSEMBLY PARTS ...
Page 67: ...07610 003 61 42 U 60 PARTS VENTLESS SYSTEM ASSEMBLY ...
Page 75: ...07610 003 61 42 U 68 SCHEMATICS 208 230 V 50 60 HZ 1 PHASE ...
Page 76: ...69 07610 003 61 42 U SCHEMATICS 460 V 50 60 HZ 3 PHASE ...
Page 77: ...07610 003 61 42 U 70 SCHEMATICS LT NB 208 230 V 50 60 HZ 1 PHASE ...
Page 78: ...71 07610 003 61 42 U SCHEMATICS LT NB 460 V 50 60 HZ 3 PHASE ...
Page 79: ...07610 003 61 42 U 72 SCHEMATICS STEAM 208 230 V 50 60 HZ 1 3 PHASE ...
Page 80: ...73 07610 003 61 42 U SCHEMATICS SDI OPTIONS ...
Page 81: ...07610 003 61 42 U 74 SCHEMATICS DRAIN QUENCH OPTION ...